FHD 33+ Trusses
Products Overview
The FHD 33+ truss system is an absolute novelty in the event industry and revolutionizes by its innovative design and the relationship between load and handling.
Contrary to the conventional FD 33 series, which is equipped with three 2 mm-thick main pipes, FHD 33+ offers a main pipe in 4 mm wall thickness. The resulting benefits are obvious: FHD 33+ combines the logistical advantage of a 3-point truss system with the high load values of a 4-point version - savings in transport and cost are the result. But that's not all: Naxpro Truss FHD 33+ remains despite the twice as high load capacity compared to its direct brother FD 33, fully compatible with FD / HD 33 and thus allows unprecedented flexibility at little truckspace.
The system is friction-locked via a conic connection. The connectors are included in delivery. To connect the truss all you need in terms of tools is a small aluminum hammer. The Naxpro-Truss FHD 33+ truss system is available in all RAL-colours and custom constructions.
Certified Safety
Dimensions
Specifications
Width: | 290 mm |
Height: | 258 mm |
Tube: | 2 pcs. 50 x 2 mm 1 pcs. 50 x 4 mm |
Diagonals: | 20 x 2 mm |
Alloy: | EN-AW 6082 T6 |
Load Chart FHD 33+
Span | Uniformly distributed load |
Deflection | Centered single load |
Deflection |
m | kg/m | mm | kg | mm |
1,0 | 1979,4 | 0,2 | 1979,4 | 0,2 |
2,0 | 987,3 | 1,7 | 1930,1 | 2,6 |
3,0 | 656,6 | 5,7 | 1282,8 | 5,9 |
4,0 | 478,9 | 13,2 | 957,9 | 10,6 |
5,0 | 304,8 | 20,6 | 762,0 | 16,6 |
6,0 | 210,2 | 29,7 | 630,6 | 23,9 |
7,0 | 153,2 | 40,5 | 536,1 | 32,7 |
8,0 | 116,2 | 53,0 | 464,6 | 42,8 |
9,0 | 90,8 | 67,1 | 408,5 | 54,4 |
10,0 | 72,6 | 83,0 | 363,1 | 67,5 |
11,0 | 59,2 | 100,6 | 325,6 | 82,1 |
12,0 | 49,0 | 119,9 | 293,9 | 98,2 |
13,0 | 41,0 | 140,9 | 266,7 | 115,9 |
14,0 | 34,7 | 163,7 | 243,0 | 135,3 |
* limited by interaction with offset / decisive is the offset on the connector
High uniformly distributed loads are to be understood ideally distributed. The load
application has to be made in the knot. The load values are calculated using 10.9
bolts. The main pipe in 4 mm wall thickness must always point straight up or down
during assembly.
Straights, Corners and Elements FHD 33+
Length | Weight | Art.-No. | Length | Weight | Art.-No. |
cm | kg | cm | kg | ||
21 | 1,07 | 300300210 | 250 | 11,63 | 300302500 |
25 | 1,28 | 300300250 | 275 | 12,79 | 300302750 |
29 | 1,48 | 300300290 | 300 | 13,95 | 300303000 |
50 | 2,55 | 300300500 | 325 | 15,11 | 300303250 |
75 | 3,83 | 300300750 | 350 | 16,28 | 300303500 |
100 | 5,10 | 300301000 | 375 | 17,44 | 300303750 |
125 | 6,38 | 300301250 | 400 | 18,60 | 300304000 |
150 | 7,65 | 300301500 | 425 | 19,76 | 300304250 |
175 | 8,93 | 300301750 | 450 | 20,93 | 300304500 |
200 | 9,30 | 300302000 | 475 | 22,09 | 300304750 |
225 | 10,46 | 300302250 | 500 | 23,25 | 300305000 |